Sponsored Links

Sabtu, 25 November 2017

Sponsored Links

Wastewater quality indicators - Wikipedia
src: upload.wikimedia.org

Wastewater quality indicators are laboratory test methodologies to assess suitability of wastewater for disposal or re-use. Tests selected and desired test results vary with the intended use or discharge location. Tests measure physical, chemical, and biological characteristics of the waste water.


Video Wastewater quality indicators



Physical characteristics

Temperature

Aquatic organisms cannot survive outside of specific temperature ranges. Irrigation runoff and water cooling of power stations may elevate temperatures above the acceptable range for some species. Elevated temperature can also cause an algae bloom which reduces oxygen levels. (See thermal pollution.) Temperature may be measured with a calibrated thermometer.

Solids

Solid material in wastewater may be dissolved, suspended, or settled. Total dissolved solids or TDS (sometimes called filterable residue) is measured as the mass of residue remaining when a measured volume of filtered water is evaporated. The mass of dried solids remaining on the filter is called total suspended solids (TSS) or nonfiltrable residue. Settleable solids are measured as the visible volume accumulated at the bottom of an Imhoff cone after water has settled for one hour. Turbidity is a measure of the light scattering ability of suspended matter in the water. Salinity measures water density or conductivity changes caused by dissolved materials.


Maps Wastewater quality indicators



Chemical characteristics

Virtually any chemical may be found in water, but routine testing is commonly limited to a few chemical elements of unique significance.

Hydrogen

Water ionizes into hydronium (H3O) cations and hydroxyl (OH) anions. The concentration of ionized hydrogen (as protonated water) is expressed as pH.

Oxygen

Most aquatic habitats are occupied by fish or other animals requiring certain minimum dissolved oxygen concentrations to survive. Dissolved oxygen concentrations may be measured directly in wastewater, but the amount of oxygen potentially required by other chemicals in the wastewater is termed as oxygen demand. Dissolved or suspended oxidizable organic material in wastewater will be used as a food source. Finely divided material is readily available to microorganisms whose populations will increase to digest the amount of food available. Digestion of this food requires oxygen, so the oxygen content of the water will ultimately be decreased by the amount required to digest the dissolved or suspended food. Oxygen concentrations may fall below the minimum required by aquatic animals if the rate of oxygen utilization exceeds replacement by atmospheric oxygen.

Basically, the reaction for biochemical oxidation may be written as:

Oxidizable material + bacteria + nutrient + O2 -> CO2 + H2O + oxidized inorganics such as NO3- or SO42-

Oxygen consumption by reducing chemicals such as sulfides and nitrites is typified as follows:

S2- + 2 O2 -> SO42-
NO2- + ½ O2 -> NO3-

Since all natural waterways contain bacteria and nutrient, almost any waste compounds introduced into such waterways will initiate biochemical reactions (such as shown above). Those biochemical reactions create what is measured in the laboratory as the biochemical oxygen demand (BOD).

Oxidizable chemicals (such as reducing chemicals) introduced into a natural water will similarly initiate chemical reactions (such as shown above). Those chemical reactions create what is measured in the laboratory as the chemical oxygen demand (COD).

Both the BOD and COD tests are a measure of the relative oxygen-depletion effect of a waste contaminant. Both have been widely adopted as a measure of pollution effect. The BOD test measures the oxygen demand of biodegradable pollutants whereas the COD test measures the oxygen demand of biodegradable pollutants plus the oxygen demand of non-biodegradable oxidizable pollutants.

The so-called 5-day BOD measures the amount of oxygen consumed by biochemical oxidation of waste contaminants in a 5-day period. The total amount of oxygen consumed when the biochemical reaction is allowed to proceed to completion is called the Ultimate BOD. Because the Ultimate BOD is so time consuming, the 5-day BOD has been almost universally adopted as a measure of relative pollution effect.

There are also many different COD tests of which the 4-hour COD is probably the most common.

There is no generalized correlation between the 5-day BOD and the ultimate BOD. Similarly there is no generalized correlation between BOD and COD. It is possible to develop such correlations for specific waste contaminants in a specific wastewater stream but such correlations cannot be generalized for use with any other waste contaminants or wastewater streams. This is because the composition of any wastewater stream is different. As an example an effluent consisting of a solution of simple sugars that might discharge from a confectionery factory is likely to have organic components that degrade very quickly. In such a case, the 5 day BOD and the ultimate BOD would be very similar since there would be very little organic material left after 5 days. However a final effluent of a sewage treatment works serving a large industrialised area might have a discharge where the ultimate BOD was much greater than the 5 day BOD because much of the easily degraded material would have been removed in the sewage treatment process and many industrial processes discharge difficult to degrade organic molecules.

The laboratory test procedures for the determining the above oxygen demands are detailed in many standard texts. American versions include the "Standard Methods for the Examination of Water and Wastewater."

Nitrogen

Nitrogen is an important nutrient for plant and animal growth. Atmospheric nitrogen is less biologically available than dissolved nitrogen in the form of ammonia and nitrates. Availability of dissolved nitrogen may contribute to algal blooms. Ammonia and organic forms of nitrogen are often measured as Total Kjeldahl Nitrogen, and analysis for inorganic forms of nitrogen may be performed for more accurate estimates of total nitrogen content.

Phosphates

Total Phosphorus and Phosphate, PO-3
4

Phosphates enter the water ways through both non-point sources and point sources. Non-point source (NPS) pollution refers to water pollution from diffuse sources. Nonpoint source pollution can be contrasted with point source pollution, where discharges occur to a body of water at a single location. The non-point sources of phosphates include: natural decomposition of rocks and minerals, storm water runoff, agricultural runoff, erosion and sedimentation, atmospheric deposition, and direct input by animals/wildlife; whereas: point sources may include: waste water treatment plants and permitted industrial discharges. In general, the non-point source pollution typically is significantly higher than the point sources of pollution. Therefore, the key to sound management is to limit the input from both point and non-point sources of phosphate. High concentration of phosphate in water bodies is an indication of pollution and largely responsible for eutrophication.

Phosphates are not toxic to people or animals unless they are present in very high levels. Digestive problems could occur from extremely high levels of phosphate.

The following criteria for total phosphorus were recommended by the U.S. Environmental Protection Agency.

  1. No more than 0.1 mg/L for streams which do not empty into reservoirs,
  2. No more than 0.05 mg/L for streams discharging into reservoirs, and
  3. No more than 0.025 mg/L for reservoirs.

Phosphorus is normally low (< 1 mg/l) in clean potable water sources and usually not regulated;

Chlorine

Chlorine has been widely used for bleaching, as a disinfectant, and for biofouling prevention in water cooling systems. Remaining concentrations of oxidizing hypochlorous acid and hypochlorite ions may be measured as chlorine residual to estimate effectiveness of disinfection or to demonstrate safety for discharge to aquatic ecosystems.


Water Quality Indicator Organisms - YouTube
src: i.ytimg.com


Biological characteristics

Water may be tested by a bioassay comparing survival of an aquatic test species in the wastewater in comparison to water from some other source. Water may also be evaluated to determine the approximate biological population of the wastewater. Pathogenic micro-organisms using water as a means of moving from one host to another may be present in sewage. Coliform index measures the population of an organism commonly found in the intestines of warm-blooded animals as an indicator of the possible presence of other intestinal pathogens.


Biochemical oxygen demand - Wikipedia
src: upload.wikimedia.org


See also

  • Biochemical oxygen demand
  • Chemical oxygen demand
  • Carbonaceous biochemical oxygen demand
  • Conventional pollutant
  • Dissolved oxygen
  • Hypoxia (environmental)
  • Industrial water treatment
  • Wastewater
  • Water pollution
  • Water quality
  • Water treatment

ISO Fast Tracks Standard for City Quality of Life รข€
src: integralcity.com


References


Drinking Water, Wastewater & Water Quality Special emphasis on NC ...
src: images.slideplayer.com


Further reading


Oman Energy & Water Conference Exhibition May 19-21, ppt download
src: slideplayer.com


External links

  • Discussion of BOD and COD (use BOD as the keyword in the pdf search function)
  • Discussion of BOD and COD (use BOD as the keyword in the pdf search function)
  • More about COD and BOD (scroll to section on "Advantage of using COD over BOD")

Source of the article : Wikipedia